Drug Discovery Assay – reference number: B020
Assay type: | Blood Vessels |
Tissue: | Human Subcutaneous Resistance Artery (Healthy) |
Target: | Adrenoceptor |
Control Compound: | Phenylephrine |
Study Type: | Wire Myography |
Functional Endpoint: | Vasodilatation |
The experiment assesses whether test articles cause vasoconstriction in human subcutaneous resistance arteries with phenylephrine as a reference compound.
Resistance arteries are involved in regulating organ specific blood flow and offer the greatest resistance to blood flowing into tissues. Resistance arteries therefore play an important role in the regulation of peripheral vascular resistance and arterial blood pressure.
Figure 1: Cumulative concentration response curve to phenylephrine in isolated human resistance arteries, demonstrating a concentration dependent contractile response. The Log EC50 = −6.11 ± 0.18M (780nM) (mean ± S.E.M), with a maximum contractile response of 63.15 ± 6.0.
The specific results that will be provided are the effects of increasing concentrations of test articles on the contractile state of human isolated subcutaneous arteries.
6 weeks from sample receipt for n = 3 donors.
Timelines are a guide based on REPROCELL Biopta’s standard tissue criteria; any client-imposed deviations to the standard tissue criteria can alter the project timelines.
Test article(s) to be provided by the Sponsor in storable aliquots at required test concentrations with information on diluent vehicle used. Stock solutions are prepared in distilled water unless otherwise requested. Bath volumes are 5mL; sponsor to provide sufficient test article to run the entire study.
In duplicate at 6 concentrations.
The experiment assesses whether test articles cause vasoconstriction in human subcutaneous resistance arteries with phenylephrine as a reference compound.
No specific exclusion criteria are in place other than to reject macroscopically diseased/necrotic tissue. Furthermore, tissues which do not respond to the standard pharmacology checks will be excluded.
All individual vessels are initially processed through standardisation and qualification procedures to ensure functionality, prior to starting the study protocol.
Vessels are processed through a standardisation procedure to reduce signal variability prior to pharmacological intervention. This ensures that vessels are maintained under appropriate physiological tension throughout the experiments.
Following standardisation, vessels are "woken up"by 2 successive high potassium salt solution challenges with washes and recovery periods following each challenge. This process standardises the basal resting tone and ensures robust contractile responses.
Vessels are then challenged with an appropriate vasoconstrictive agent before endothelial function is assessed by the addition of the appropriate endothelial dependent vasorelaxant agent. Test tissues are then washed, and the responses allowed to return to baseline.
Vessels which pass the standardisation and qualification pass/fail criteria will then progress to the study protocol.
To assess their ability to elicit vasoconstriction, 6 point cumulative concentration response curves (CCRC’s) will be performed for each test article. These CCRC’s will be performed from resting baseline tension. A positive control compound and representative test article vehicle CCRC will also be run to allow direct comparison with test articles.
An example of the conditions assessed for 3 test articles are detailed below (each condition will be run in duplicate vessels):
Representative test article vehicle CCRC
Positive control CCRC
Test article 1 CCRC
Test article 2 CCRC
Test article 3 CCRC
To assess the involvement of a specific receptor subtype in any observed responses, the concentration of test article eliciting the largest response can subsequently (following a wash out and recovery period) be tested in the presence of a specific antagonist. This supplementary option will incur an extra charge.
To assess the ability of each test article to antagonise an agonist mediated vasoconstriction response, 6 point cumulative concentration response curves (CCRC’s) will be performed for each test article. These CCRC’s will be performed following pre-constriction with an appropriate vasoconstrictive reference agonist. A positive control compound and representative test article vehicle CCRC will also be run to allow direct comparison with test articles.
An example of the conditions assessed for 3 test articles are detailed below (each condition will be run in duplicate vessels):
Representative test article vehicle CCRC
Test article 1 CCRC
Test article 2 CCRC
Test article 3 CCRC
Positive control CCRC
To assess the ability of a test article to antagonise an agonist mediated vasoconstriction response; 6 point cumulative concentration response curves (CCRC’s) will firstly be performed for the vasoconstrictive reference agonist.
Following a wash out and recovery period, vessels will be incubated with the test article (3 different concentrations of test article will be assessed), positive control or test article vehicle before the same 6 point cumulative concentration response curve will be repeated for the reference agonist.
An example of the conditions assessed for 3 test articles are detailed below (each condition will be run in duplicate vessels):
Representative test article vehicle
Test article 1 concentration 1
Test article 1 concentration 2
Test article 1 concentration 3
Test article 2 concentration 1
Test article 2 concentration 2
Test article 2 concentration 3
Test article 3 concentration 1
Test article 3 concentration 2
Test article 3 concentration 3
Positive control
Responses shall be expressed either in milligrams or grams tension, or as a % of the maximal contractile response (e.g. KPSS). Statistical analysis (where appropriate) will be performed using GraphPad Prism, with the results being shown in graphical form in the final report.
Back to the Drug Discovery Assay Catalog »
Predictive Drug Discovery Assay Services
Online Resources
22-25 March 2021 / Virtual Meeting
We are participating in Europe’s largest Springtime Biotech Partnering Digital Event. Please schedule a virtual meeting with us!
REPROCELL
Products
Services
© 2021 REPROCELL Inc. All rights reserved.
REPROCELL Inc. 日本語 MetLife Shin-yokohama 381, Bldg. 9F, 3-8-11 Shin-yokohama, Kohoku-ku, Yokohama, Kanagawa 222-0033, Japan
REPROCELL USA Inc. 9000 Virginia Manor Road, Suite 207, Beltsville, 20705, USA
REPROCELL Europe Ltd. Thomson Pavilion, Todd Campus, West of Scotland Science Park, Acre Road, Glasgow, G20 0XA, United Kingdom
Bioserve Biotechnologies (India) PVT Ltd. Unit: D4-D7, 1st Floor, Industrial Estate, Moula Ali, Medchal-Malkajgiri Dist., Hyderabad-500040, Telangana, India